Testing capacity The smallest unit is a basic unit. An extension unit can be connected to a basic unit. Basic and extension units are equipped with 2 luminaire measuring circuits and 16 thermocouple inputs. 1 or 2 flame luminaires can then be connected (up to 4 with the extension unit). Several test samples can be tested simultaneously. Dimensions 500x500x300mm (wxhxd) per unit Control and measurement data acquisition TopMessage-System (Delphin product) Network capability, scalable Recording and preparation of all measurement data Control of relay matrix and power switches Electrical connections 2 luminaire measuring circuits available per unit 4mm connectors for the electrical connections Windings of ballast and transformers measured in 4 wire technique Test voltage connection via multi-pole high-voltage plugs Temperature measurement 16 thermocouple inputs per unit Equipped with all standard types, e.g. K,J,L Full potential isolation | Temperature range Type K: -50 to 1232 °C Type J: -50 to 1078 °C Automatic compenstion of reference temperature Probe connection via miniature thermo plug connection Ambient temperature measurement via high accuracy RTD (probe included in delivery) Resistance measurement R-cold and R-warm measurement Resistance range 0 to 10 kOhm Precise resistance measurement through 4-wire technology Automatic measurement-current adaptation Automatic calculation of winding temperature Electrical measurement Voltage, Current, Power primary and secondary testing Voltage, Current, Power of lamp Full potential isolation Voltage range 0 to 500 Volts Current range 0 to 1 A, 10 A, 20 A via shunt (for low voltage luminaires only) Power range Depends on voltage and current ranges Automatic selection of measurement range |